Building Information

Typical High Zone

GLA: 2,120.29 – 2,251.57 sqm
NUA: 1,859.29 – 1,977.78 sqm
Efficiency: 88%
Key Features: Column free & open floor plates create optimal planning flexibility

Should you wish to download the Makati Commerce Tower Floor Plan, click here.

Typical Mid Zone

GLA: 2,178.20 sqm
NUA: 1,920.54 sqm
Efficiency: 88%
Key Features: Column free & open floor plates create optimal planning flexibility

Should you wish to download the Makati Commerce Tower Floor Plan, click here.

Construction Updates

Construction has completed and Makati Commerce Tower is now ready for occupancy.

Technical Specifications

Air-Conditioning System

  • Centralised water-cooled chilled water system
  • Use of environmentally friendly HFO (R-514a) refrigerant with zero ozone depletion potential (ODP) and very low global warming potential (GWP)
  • Air system: variable speed FCU, AHU and PAHU
  • Ventilation: Demand Control Ventilation (DCV)

Telecommunications

  • 4 telco rooms for 4 telco providers with 1 combiner room and 1 MDF/CATV room
  • 2 service entrance points for main and redundant

Energy

  • Power load per floor: 100 VA per sqm
  • Back-up power: 100%
  • No. of gensets: 5 units 2000KW with N+1 configuration
  • Fuel storage capacity: 48 hours full operational
  • Downtime: within 20 seconds
  • Redundant power capacity: redundant busduct for office

Standard Landlord Provision

  • Bare shell floor
  • Double-glazed window curtain wall system with thermal insulations
  • Fire sprinkler system
  • Power: 180VA/sqm per office floor (excluding cooling power)
  • Air-conditioning: 22-20 sqm/TR of chilled water cooling capacity
  • Flooring: 50mm provided for tenant’s screed and carpeting

Energy and Water Saving Features

  • Save approximately 26% on energy usage and approximately 43% on water consumption

Indoor Air Quality Feature

  • Wall-mounted CO2 sensors monitor CO2 level in accordance with strict local and international standards

  • MERV-8 (30-35% DSE) pre-filter and MERV-17 (99.97% efficiency on 0.3 pm particles) and addition of ultraviolet lamps to filter Air Handling Units (AHU’s) coils and air streams

  • Exhaust vents installed across all office spaces, toilets and storage rooms and connected to the Primary Air Handling Units (PAHU’s) equipped with an energy recovery wheel

  • Dedicated FCU to ensure optimal air quality that will not mix with other tenants

  • Positive air pressure helps avoid infiltration of untreated outdoor air which may contain pollutants and harmful contaminants

  • Each tenant will have its own thermostat control in order to dial in on the perfect temperature setting for optimal comfort and efficiency

  • Fresh air supply to the building is pre-cooled using a dedicated primary air handling unit (PAHU) decoupled from the indoor units (AHU and FCU), resulting in better indoor air quality (relative humidity) and higher energy savings on the AC system

Should you wish to download the Makati Commerce Tower Specification Sheet, click here.